MIL-W-16878/6 Type ET

Conductor: Silver Plated Copper
Insulation: PTFE
Temperature Rating: 200°C
Operating Voltage: -65°C to 200°C
Applications: Point-to-point wiring of electronic equipment where temperatures up to 200°C are required
Approvals: Meets the requirements of M16878.

250 Volts 200°C Type ET

Replace * with number from Color Code Chart “Hook Up Wire”

SKU Wire Gauge Number of Strands Nominal Insulation Nominal Outside Diameter Mil Spec Number Weight LBs per 1000 FT
A37C01-* 30 1 0.006 0.022 M16878/6-BBA-* 0.665
A37C02-* 28 1 0.006 0.025 M16878/6-BCA-* 0.92
A37C03-* 24 1 0.006 0.032 M16878/6-BEA-* 1.91
A37C04-* 24 7 0.006 0.036 M16878/6-BEB-* 1.94
A37C05-* 24 19 0.006 0.036 M16878/6-BEE-* 2
A37C08-* 22 1 0.006 0.038 M16878/6-BFA-* 2.8
A37C09-* 22 7 0.006 0.042 M16878/6-BFB-* 2.84
A37C10-* 22 19 0.006 0.042 M16878/6-BGE-* 3.01
A37C13-* 20 1 0.006 0.044 M16878/6-BGA-* 4.23
A37C14-* 20 7 0.006 0.05 M16878/6-BGB-* 4.28
A37C16-* 20 19 0.006 0.05 M16878/6-BGE-* 4.56
A37C80-* 26 1 0.006 0.028 M16878/6-BDA-* 1.29
A37C81-* 26 19 0.006 0.031 M16878/6-BDE-* 1.34
A37C89-* 28 19 0.006 0.027 M16878/6-BCE-* 0.957
A37C90-* 26 7 0.006 0.031 M16878/6-BDB-* 1.32
A37C95-* 28 7 0.006 0.027 M16878/6-BCB-* 0.925